74 mm and can be supplied in R or S design.
The standard width is 38 mm. Using our standard installation method, the gap between the ribs is 12 mm. You can also combine different dimensions.
RIB-R
38 mm
13 mm
44 mm
34 mm
28 mm
22 mm
88 mm
28 mm
22 mm
RIB-S
74 mm
64 mm
54 mm
44 mm
38 mm
34 mm
28 mm
22 mm
13 mm
88 mm
28 mm
22 mm
GUSTAFS ACOUSTIC LINEAR RIBS
ACOUSTICS
Sound
absorption
Typ
Spacing
Slott
(D)
Ribs on
cc
Open
area
Linear 12 mm
∞ 50 mm 24%
Linear* 12 mm
∞ 50 mm 24%
Linear 62 mm
∞ 100 mm 62%
* Tested with 17 mm insulation only, no air void
WALL: 45 mm insulation + 30 mm air void (Hz/αp )
αw
0,70-C
0,65-C
-
CEILING: 45 mm insulation + 200 mm air void (Hz/αp )
NRC
125
250
500
1000
2000
4000
0,80
0,70
-
0,30
0,05
-
0,90
0,35
-
1,00
0,90
-
0,75
0,90
-
0,60
0,70
-
0,65
0,65
-
αw
0,70-C
0,95-A
NRC
125
250
500
1000
2000
4000
0,80
1,00
0,50
0,35
0,95
0,95
0,85
1,00
0,75
1,00
0,60
0,95
0,65
Gustafs Linear System / W ... ascunde
Pentru noi, confidențialitatea dvs. este importantă
Portalul spatiulconstruit.ro folosește cookies pentru a asigura funcționalitatea și securitatea site-ului, pentru a personaliza conținutul și modul de interacțiune, pentru a oferi facilități de social media
și pentru a analiza modul în care este utilizat site-ul. Aceste cookies sunt stocate și prelucrate, de către noi sau partenerii noștri în conformitate cu toate reglementările în vigoare și toate standardele
de confidențialitate și securitate actuale.
Vă rugăm să rețineți că este posibil ca anumite prelucrări ale datelor dumneavoastră cu caracter personal să nu necesite consimțământul dumneavoastră, dar vă puteți exprima acordul cu privire la prelucrarea
realizată de către noi și partenerii noștri conform descrierii de mai sus utilizând butonul SUNT DE ACORD de mai jos.
Navigând în continuare, vă exprimați acordul implicit asupra folosirii cookie-urilor.