Sistem de parcare hidraulic KLAUS TRENDVARIO 4100
Dimensions
Car data
Free space
145
Dimensions
GF (ground floor)
Page 4
Function
Load plan
Page 5
Electrical
installation
Single parking spaces can
Loadable
also be upgraded to handle
up to 2600 kg! heavier loads at a later date!
Tolerances for space requirements + 03.
Dimensions in cm.
Suitable for
Standard passenger cars:
Limousine, station wagon, SUV, van
according to clearance and maximal
surface load.
LF (lower floor)
To be performed by the
customer
Water drainage
7
550 +50 for vehicle up to 5.00 m = 16’4’’ long
(570 +50 for vehicle up to 5.20 m = 17’ long) 9
1
2
3
4
5
6
7
car height
GF
LF
200
150
15°
100
height
220
Standard type
Special system: maximum load for extra charge.
To follow the minimum finished dimensions, make sure
to consider the tolerances according to VOB, part C
(DIN 18330 and 18331) and the DIN 18202.
Car width for platform width 230 cm. If wider platforms
are used it is also possible to park wider cars.
If height H is larger, vehic
les with the maximum height as
applicable for the GF can be parked on the UF, otherwise
there will be free space available on the ceiling.
Potential equalization from foundation grounding connection
to system (provided by the customer).
Slope with drainage channel and sump.
6°
500 (520)
125
13°
4100-230
200
175
height
220
8
4100-200
220 5
4100-175
25
30
160
5
8
2%
235
Description
2%
car height
GF
LF
200
175
8
9
10
230
40
Page 7
Clearance profile
10
45
Page 6
6
see table
Grounding
Standard
Special 2
4
width
190 cm
190 cm 4
weight
max. 2000 kg max. 2600 kg
wheel load
max. 500 kg max. 650 kg
220 5
Technical
data
3
55
25
45
Page 3
Width
dimensions
Approach
Free spaces
2000 kg 1 / 2600 kg 2
Detail doors
see page 2
Page 2
Door
Width
dimensions
PRODUCT DATA
KLAUS Multiparking GmbH
Hermann-Krum-Straße 2
D-88319 Aitrach
Fon +49 (0 ) 75 65 5 08-0
Fax +49 (0 ) 75 65 5 08-88
info@multiparking.com
www.multiparking.com
Section
h
height
235
car heigh
t
GF
LF
205
205
These floor areas need to be horizontal and on equal level
across the full width of the pit
For convenient use of your parking space and due to the fact
that the cars keep becoming longer we recommend
a pit length of 570 cm.
At the transition section between pit floor and walls no hollow
mouldings/coves are possible. If hollow mouldings/coves are
required, the systems must be designed smaller or the pits
accordingly wider.
If sprinklers are required make sure to provide the
necessary free spaces during the planning stage.
TrendVario 4100 | Code numbe 585.32.110-009 | Version 11.2013
Page 1
Technical
data
Page 6
H2
H3
H
11
25 13
GT
175
200
230
Type
4100
4100
4100
550 (570)
H
220
220
235
H1
200
200
205
H2
210
210
220
Type
4100
4100
4100
Columns per each grid unit
To be performed by the
customer
RB
10
Page 7
Description
RB
(B2)
B1
B2
GT
175
200
230
550 (570)
H
220
220
235
H1
200
200
205
H2
220
220
230
Type
4100
4100
4100
Columns per each grid
unit
no. of grids x RB + 20
2
Carriageway in accordance
with local regulations
RB 12
250
260
270
280
290
B1
250
260
270
280
290
B2
230
240
250
260
270
Columns every second grid unit
RB
10
RB
(B4)
B3
RB
B4
usable platform width
230
240
250
260
270
RB 12
250
260
270
280
290
B3
500
520
540
560
580
Columns every second grid unit
10
20
no. of grids x RB + 20
Carriageway in accordance
with local regulations
B4
480
500
520
540
560
H1
200
200
205
H2
210
210
220
H3
220
220
230
RB
(B2)
B1
B2
RB
20
no. of grids x RB + 20
Carriageway in accordance
with local regulations
RB
RB
H
220
220
235
RB
10
C 20
usable platform width
230
240
250
260
270
GT
175
200
230
550 (570)
Columns per each grid unit
Not available!
RB
GT
H
RB
RB
(B4)
B3
no. of grids x RB + 20
20
Carriageway in accordance
with local regulations
usable platform width
230
240
250
260
270
RB 12
250
260
270
280
290
B3
500
520
540
560
580
B4
480
500
520
540
560
RB 12
250
260
270
280
290
B1
250
2
60
270
280
290
B2
230
240
250
260
270
Columns every second grid unit
RB
RB
B4
usable platform width
230
240
250
260
270
RB
10
(B4)
B3
RB
RB
B4
(25) 13
Page 5
Electrical
installation
Sliding door in front of columns
(25) 13
Page 4
Function
Load plan
25
13
30
Page 3
Width
dimensions
Approach
Free spaces
Sliding door between columns
H1
H1 11
Page 2
Door
Width
dimensions
25
13
H2
H
Sliding door behind columns
GT
Car data
H1 11
Dimensions
Page 2 of 7
Garages with sliding doors (standard) | Widths dimensions
H2
H
Section
TrendVario 4100 | Code number 585.32.110-009 | Version 11.2013
GT
Page 1
20
no. of grids x RB + 20
Carriageway in accordance
with local regulations
usable platform width
230
240
250
260
270
RB 12
250
260
270
280
290
B3
500
520
540
560
580
B5
480
500
520
540
560
According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
and then once a year, the gate has t
o be inspected by an expert and the findings entered in the inspection book. The inspection has
to be carried out independent of any maintenance work.
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm.
Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and
individual driving behaviour and capability).
11
12
13
For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing
manoeuvring radius).
H1 = Heigth of the vehicle on ground floor platform.
RB = Grid unit width must strictly conform to dimensions quoted!
Only applies to manually operated doors. The electrically driven doors must have 35 cm.
Page 1
Section
Dimensions
Car data
TrendVario 4100 | Code number 585.32.110-009 | Version 11.2013
Page 3 of 7
Garages with roll doors | Widths dimensions
Roll door behind columns
Columns pe
r each grid unit
50
Page 2
Door
Width
dimensions
20
B5
20
B5
20
20
Carriageway in accordance
with local regulations
usable platform width
230
240
250
260
270
Page 5
Electrical
installation
Technical
data
RB
no. of grids x RB + 20
570 (550)
Page 4
Function
Load plan
RB
10
2
220
Page 3
Width
dimensions
Approach
Free spaces
RB
RB 12
250
260
270
280
290
B5
230
240
250
260
270
According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has
to be carried out independent of any maintenance work.
Page 6
To be performed by the
customer
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm.
Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and
r each grid unit
50
Page 2
Door
Width
dimensions
20
B5
20
B5
20
20
Carriageway in accordance
with local regulations
usable platform width
230
240
250
260
270
Page 5
Electrical
installation
Technical
data
RB
no. of grids x RB + 20
570 (550)
Page 4
Function
Load plan
RB
10
2
220
Page 3
Width
dimensions
Approach
Free spaces
RB
RB 12
250
260
270
280
290
B5
230
240
250
260
270
According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,
and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection has
to be carried out independent of any maintenance work.
Page 6
To be performed by the
customer
For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm.
Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and
... ascunde
Alte documentatii ale aceleasi game Vezi toate
Fisa tehnica
6 p | EN
MULTIBASE 2072i
Fisa tehnica
7 p | EN
MULTIBASE 2072i